beckysteel0212@gmail.com +86 86151827

Logo

distal femoral medial sheet

We operate a variety of standard steel plates, steel coils, steel strips, steel pipes and galvanized products. We can also provide you with deep processing services such as welding, drilling, cutting, and bending. If you have any requirements for steel products, please click the button below to contact us immediately!
Show
Details

results for this questionAre there any Osteotomy plates on the distal third of the femur?Are there any Osteotomy plates on the distal third of the femur?Condylar Plates,95° Fractures and revisions of the proximal and distal third of the femur in skeletally mature patients.Osteotomy Plates 90°/100°/110°/120°/130°Hip Plate Osteoto- mies on the proximal femur in skeletally mature patients.No contraindication specific to these devices.Instructions for Use Plate and Screw Implants results for this questionFeedbackWhat are Medial Femoral Condyles? (with pictures)

The medial femoral condyles are also distinguished by another anatomical term of location.Medial in anatomy means toward the midline of the body,as opposed to lateral,or toward the sides of the body.As such,the vertical ligament found along the inside of the knee that attaches to this bony protrusion of the femur is known as the medial collateral ligament (MCL),while that along the results for this questionHow is the medial closing wedge distal femoral osteotomy treated?How is the medial closing wedge distal femoral osteotomy treated?present a surgical technique for the medial closing-wedge distal femoral osteotomy using an anteromedial-distal femoral locking plate.A bnormal mechanical alignment of the lower ex- tremity is a risk factor for progressive joint degen- eration.1Traditionally,valgus alignment with lateral compartment knee osteoarthritis was treated with aMedial Closing-Wedge Distal Femoral Osteotomy for Genu Valgum Wit

results for this questionWhat are the symptoms of a distal femur fracture?What are the symptoms of a distal femur fracture?Most common symptoms of distal femur fracture include Pain with weight bearing Swelling and bruising Tenderness to touch Deformity.Distal femoral fracture - Physiopedia5/5Estimated Reading Time 8 minsMedial Closing-Wedge Distal Femoral Osteotomy for

the distal insertion of the vastus medialis oblique,can be incised to allow mobilization of the quadriceps and adequate exposure of the distal femur for plate posi-tioning.The intermuscular septum adjacent to the medial femoral cortex is then incised in line with the femur using electrocautery.AA Simple Method of Measuring the Distance From the The mean distance from the medial distal femoral physis to the Schöttle point was 7.27 ± 1.78 mm.The Schöttle point was distal to the medial distal femoral physis in all cases.There was no significant correlation between age and mean distance in either the overall study population (r = 0.046,P = .798)

Author Anchul Kumar Pahadiya,Narendra Joshi,Rakesh Dhukia,Vishal Shekhawat,Deependra SinghPublish Year 2021Instructions for Use Plate and Screw Implants

Slipped Capital Femoral Epiphysis (SCFE) Screw System Spring Plates 3.5 Standard DHS Lag Screw with LCP DHHS Sideplate The Calcaneal Plate The Locking Calcaneal Plate TomoFix TomoFix Medial Distal Femur (MDF) TomoFix Medial High Tibial Plate (MHT) VA-LCP Ankle Trauma System 2.7/3.5 VA-LCP Anterior Clavicle Plate VA-LCP Condylar Plate 4.5/5.0 VA Author Maley Deepak Kumar,Roop Singh,Rakesh Khiyani,Kiranpreet Kaur,SvareenPublish Year 2019Distal femoral torsional osteotomy increases the contact Unlike on the medial facet,a significant consistent increase of peak pressure from 0° to 90° flexion could be shown (p = 0.022) on the lateral patella aspect.Conclusion Distal femoral torsional osteotomy to correct pathological femoral antetorsion leads to a redistribution of retropatellar pressure.External derotation leads to an increased peak pressure on the medial patellar facet and can impairComparative study of distal femoral locking compression Keywords TENS nail,varus angulation,distal femur fracture with intercondylar extension,medial femoral defect Introduction Distal femoral fractures are fractures within the distal 15 cm of the femur,which includes the epiphysis and the articular surface [1].According to Muller,this fracture is

Distal Femur Fracture - TeachMeSurgery

Jul 15,2020·Introduction Distal femur fractures are fractures extending from the distal metaphyseal-diaphyseal junction of the femur to the articular surface of the femoral condyles.They account for around 3-6% of femur fractures.Distal Femur Fractures - Trauma - Orthobulletsmedial condyle extends more distal than lateral distal femur becomes trapezoidal in cross-section towards the knee lateral cortex of femur slopes ~10 degrees,medial cortex slopes ~25 degrees in the axial plane posterior halves of both condyles are posterior to the posterior cortex of femoral shaftDistal Femur Fractures Musculoskeletal KeyAug 27,2016·Chapter 80 Distal Femur Fractures Eric M.Lindvall,Anthony F.Infante,Jr.,Roy Sanders Anatomy General Anatomy The distal femur extends for approximately the distal third of the femur.23,28,70 It begins as the canal gradually widens and the cortices thin and continues distally to the joint line.The supracondylar region (distal metaphysis) flares medially greater

Distal Femur Fractures Presentation and Treatment Bone

The distal femur is the area where the stronger diaphyseal bone meets the thinner and weaker metaphyseal bone.The anatomical axis of the knee joint does not coincide with the weight-bearing axis which crosses the center of the femoral head and the center of the knee.The anatomical axis is in valgus and subtends an angle of 81° with the knee Distal femoral fracture - PhysiopediaDefinition/DescriptionClinically Relevant AnatomyMechanism of Injury / Pathological ProcessClinical PresentationDiagnostic ProceduresManagement / InterventionsPhysical Therapy ManagementComplicationsA Fracture that occurs at the distal end of the femur bone,which includes the femoral condyles and the metaphysis.Most common types of distal femur fractures 1.Transverse fractures 2.Comminuted fractures 3.Intra-articular fracturesSee more on physio-pediaDistal Femoral Osteotomy PlatePre-operative Planning Figures 1 2 shows medial patellar luxation as a result of distal femoral varus.Pre-operatively the appropriate ostectomy angle necessary to straighten the femur is drawn on the x-ray as noted in Fig.3.Distal femoral replacement for Fracture around a loose Distal femoral replacement.1.Introduction.The distal femoral replacement prosthesis is indicated when there is either insufficient bone stock or poor bone quality.The tibial component requires revision to be compatible with the new distal femoral replacement.2.Preoperative planning.

Estimated Reading Time 11 minsTKR Distal Femoral Resection Wheeless' Textbook of

Distal femoral resection at knee replacement - The effect of varying entry point and rotation on prosthesis position.Distal femoral cut perpendicular to mechanical axis may induce varus instability in flexion in medial osteoarthritic knees with varus deformity in total knee replacement a pitfall of the navigation system.Evaluation of results of open distal femur fractures with Dec 01,2019·Incision and approach to distal femur varied with the location of the open wounds which were liberally extended proximally and distally,except in cases of medial wound where the wound was extended for debridement only and standard lateral or modified swashbuckler approach was used in such cases.8 Second inspection of the wound and radical debridement consisting of excision of devitalizedFemur Diaphysis Musculoskeletal KeyJun 04,2017·Femoral length can be measured with a meter stick and fluoroscopy.It is important,that (1) the target structure (upper end of femoral head,distal end of the medial femoral condyle) are always in the center of the image and (2) the meter stick is held in a consistent way (parallel

Femur bone anatomy Proximal,distal and shaft Kenhub

Jun 17,2021·The relationship of the femur with its proximal and distal articulations is rather unique.Firstly,the neck of the femur is angled superomedially in order to fit into the acetabulum.An ideal angle between the inferior margin of the femoral neck and the medial surface of the femoral shaft should be between 120 and 130 degrees.File Size 1MBPage Count 32Distal Femur (Thighbone) Fractures of the Knee - OrthoInfo Distal femur fractures that enter the the knee joint may heal with a defect in the normally smooth surface of the joint.Because the knee is the largest weightbearing joint in the body,any defect can damage the protective articular cartilage and,over time,result in arthritis.Images of distal femoral medial Sheet imagesMedial approach to the distal femur - AO FoundationMedial approach to the distal femur.1.Principles.The medial approach to the distal femur is useful to expose medial distal femoral fractures,a Hoffa-type fracture.It is also useful to expose the neurovascular bundle when a distal femoral fracture is complicated by an arterial injury.The approach can be extended to expose the posterior cruciate ligament.

Knee Radiology Key

Apr 09,2020· Distal femur Medial femoral condyle larger than lateral Anteriorly,V-shaped trochlear groove accommodates patella Proximal tibia 3-layered fascial sheet between patella and medial femoral condyle Superficial layer Investing fascia of thigh (crural fascia)LCP Condylar Plate 4.5/5.0.Part of the LCP Periarticular most distal 5.0 mm screw holes in the head of the plate are parallel to the femoral joint axis. that the plate is properly oriented on the condyle under lateral C-Arm image.Because the shaft of the femur is frequently out of alignment with the distal fragment,proper plateLower Limb Alignment Radiology KeyJun 21,2020·Logically,the medial and lateral angles relative to an axis add up to 180°.The usual practice is to state the angle that normally measures less than 90°.By general consensus,the proximal femoral angles are measured relative to the anatomic axis on the medial side and relative to the mechanical axis on the lateral side.

Medial Closed Wedge Distal Femoral Osteotomy Using a

edial closed wedge distal femoral osteotomy (MCWDFO) is widely performed for valgus knee with lateral-compartment osteoarthritis when the deformity center is located at the distal femur.Although favorable short- to mid-term results have been reported since the development of a biplanar osteotomy with existing plates,1,2 the following problems remain,NCB Distal Femur System - Zimmer BiometNCB&Distal Femur Surgical Technique Distal Femur System Surgical Technique 5 Cable Fixation Options The following products from the Zimmer&Cable-Ready&Cable Grip System are compatible with the NCB Distal Femur System See data sheet REF 97-2232-015-00 for more specific instructions.Cable Fixation with Hex ButtonOriginal Article Clinical efficacy of augmented medial Keywords Distal femoral fracture,medial plate,nonunion Introduction Distal femoral fractures (DFF) account for 4-6% of femoral fractures,and most cases are caused by high-impact injury and characterized by multiple onset,comminution,instability,and easy spread to

PERI-LOC Periarticular Locked Plating System for Upper and

Download the Anterolateral Distal Tibia Sales Sheet for more information.Features of the Medial Distal Tibia Locked Plate.Features a beveled tip proximally to allow easy percutaneous insertion; Holes in the plate can be used for 1mm of compression or locking and it is anatomically contoured to match the distal tibia.Surgical TechniquesPERILOC Periarticular Locked Lower Extremity Plating Download the Anterolateral Distal Tibia Sales Sheet for more information.Features of the Medial Distal Tibia Locked Plate.Features a beveled tip proximally to allow easy percutaneous insertion; Holes in the plate can be used for 1mm of compression or locking and it is anatomically contoured to match the distal tibia.Surgical TechniquesPeople also askWhen to use the medial approach to the distal femur?When to use the medial approach to the distal femur?The medial approach to the distal femur is useful to expose medial distal femoral fractures,a Hoffa-type fracture.It is also useful to expose the neurovascular bundle when a distal femoral fracture is complicated by an arterial injury.The approach can be extended to expose the posterior cruciate ligament.Medial approach to the distal femur - AO Foundation

Post-Operative Instructions Distal Femoral Osteotomy

Distal Femoral Osteotomy Day of surgery A.Diet as tolerated B.Icing is important for the first 5-7 days post-op.While the post-op dressing is in place,icing should be done continuously.Once the dressing is removed on the third post-operative day,ice is applied for 20-minute periods 3-4 times per day.Product Fact Sheets JJ Medical DevicesTomoFix&Medial Distal Femur Plate; TomoFix&Medial High Tibia Plate; ViviGen& ViviGen Formable&Cellular Bone Matrix; Trauma Products.2.4 mm LCP&Distal Radius System; 2.4 mm Variable Angle LCP Distal Radius Sterile Kit; 2.4 mm Variable Angle LCP Two-Column Volar Distal Radius Plate; 2.4/2.7mm Variable Angle LCP&Forefoot/Midfoot SystemRelated searches for distal femoral medial sheetmedial femoral epicondylemedial femoral condylefemoral medial condyle fracturemedial femoral condyle injurymedial and lateral femoral condyledistal femoral metadiaphysismedial femoral condyle contusionmedial femoral compartment12345Next

Retrograde Femoral Nailing System (RFN-Advanced

The Retrograde Femoral Nailing System (RFN-Advanced System) is designed to improve fixation by reduced toggle and loss of reduction for distal femur fractures 1.As part of the Advanced Nailing System,it is designed for simple to complex cases 4 with increased fixation and stability 1-6 and intuitive,connection instrumentation.8.Request TomoFix Medial Distal Femur Plate.For closed-wedgeThe TomoFix Medial Distal Femur (MDF) Plate is designed according to locking compression plate (LCP) principles.In the distal section there are four threaded holes,the directions of which are adapted to the anatomy of the supracondylar femur.There are four Combi holes in the proximal shaft section.A right and left version of the plate allow for accurate positioning of the anteromedial section of the distal femur and secure anchoring of the locking screws in the femoralZimmer&Periarticular Distal Femoral Locking Plate The Zimmer Periarticular Distal Femoral Locking Plate is designed to be placed slightly anteriorly on the distal femoral condyles.In order to achieve an accurate lateral x-ray or c-arm image,it will be necessary to externally rotate the affected limb 20-30.As in distal targeting of

[Short-term effectiveness of derotational distal femoral

Mar 01,2021·[Short-term effectiveness of derotational distal femoral osteotomy combined with medial patellofemoral ligament reconstruction for recurrent patellar dislocation].Yuan Li Department of Orthopaedics,the Affiliated Hospital of Southwest Medical University Sichuan Provincial Laboratory of Orthopaedic Engineering,Luzhou Sichuan,646000,P.R.China.

More
Contact Us
Name:
E-mail:
*
Tel:
Messages:

Classification

Craft
Cutting
Roilling
Bending
Plasma
Shearing
Equipment
Welding Machine
Planer
Drilling Machine
Milling boring Machine
Vertical Lathe
Cutting Machine
Navigate
News
Service
Products
Hot Sale
About us
Contact us
Online
Quote
Message

Show

Topic

Your message

If you have relevant needs, you can leave your contact information below, we will reply to you within 24 hours, thank you for your attention.

More News
Hot Sale
Case
Deep process
Copyright © 2012 M-chine |